Get a Quote
← Back to Products
Home / Products / Concrete Filter Plate / Technical Reference

Concrete Filter Plate · Technical Reference & Specifications

Precast concrete plates for filter tank bottoms — plate construction, nozzle hole and socket layout, the bedding and levelling sequence, specification data and applications.

← Back to Concrete Filter Plate

What a concrete filter plate is

A concrete filter plate is a flat precast concrete panel that forms the bottom — the nozzle deck — of a water or wastewater filter. Each plate carries a regular grid of holes or cast-in sockets, and a filter nozzle is fitted into every position so that backwash water and process air are distributed evenly over the whole filter area and collected again during filtration.

The plates are cast on a casting jig, cured, and then lifted into the filter basin on site. Inside the tank they are bedded on mortar strips and levelled individually, the joints between plates are sealed, and the filter nozzles are fitted. The support layer of graded media and the filter bed itself are then placed on top of the finished deck.

Because the panel is precast, the tank floor is assembled from finished, checked elements rather than poured in place. This suits both new filters and the reconstruction of an existing filter bottom, where the old deck is broken out and replaced with new plates set to a common level.

Plate construction and nozzle layout

The plate is a reinforced concrete panel, cast in a steel mould. Its two working features are the hole grid and the way the nozzles are held in it.

The exact hole pattern, socket type and reinforcement are set by the project drawing and the nozzle chosen — they are confirmed per order rather than taken from a fixed catalogue.

How a precast filter bottom is installed

The method is fixed by the contractor's method statement; the sequence below describes how the plates are normally laid.

  1. Basin preparation. The filter is drained and cleaned, and the existing bottom or the structural slab is checked for level and soundness and repaired where needed.
  2. Bedding strips. Mortar bedding strips are laid on the tank floor along the plate supports, to a level that sets the finished nozzle deck height.
  3. Bedding and levelling. The plates are lifted in and bedded one by one, each plate being set to the line and level of the deck before the bedding sets.
  4. Joints. The gaps between adjacent plates are filled and finished so the deck reads as one continuous, tightly closed surface with no step at the joints.
  5. Hole and socket check. Every hole or socket is checked for position, level and clearance — and cleared of mortar or debris — before the nozzles are fitted.
  6. Nozzle installation. The filter nozzles are fitted into the plate, checked for tightness and for a common top level across the deck.
  7. Support layer and media. The graded support layer is placed on the finished deck, followed by the filter media, with the nozzle height and the media grading matched to the filtration duty.

Filter nozzles are supplied separately and matched to the plate; media for the support layer and the filter bed is quoted to suit the filtration duty.

Precast plates or a cast-in-place bottom

Both options give a filter a concrete nozzle deck; the choice is usually driven by the tank, the programme and the access.

PointPrecast concrete filter plateCast-in-place filter plate
Where it is madeCast and cured off site, then lifted into the basinFormed, poured and cured inside the filter tank
Site workBedding, levelling, jointing and nozzle fittingFormwork, socket setting, reinforcement, pour and curing in the tank
Joints in the deckJoint between each plate, filled and finished on siteNo joints between separate plates
Typical useStandard filter bays; bottom replacement and upgrading where the tank access suits platesTanks whose plan shape makes an assembly of plates awkward, and filters needing a continuous slab tied to the tank walls

Related: BS Cast-in-place Filter Plate — the monolithic poured filter bottom.

Specification data

Configuration is confirmed against the project drawing. Parameters marked on request are quoted for the specific plate, nozzle grid and tank rather than taken from a fixed catalogue.

ParameterValue
Product typePrecast concrete filter plate for filter tank bottoms
Standard plate sizes980 × 980 mm · 980 × 1140 mm · 1140 × 1140 mm
Other plate sizesOn request — made to your tank drawing
Plate thicknessOn request
Concrete gradeOn request
Reinforcement & lifting provisionOn request
Nozzle holes / socketsOn request — plain holes or cast-in sockets, to the required grid
Nozzle hole diameter / threadOn request — matched to the filter nozzle
Nozzle grid / spacingOn request
Plate surfaceFlat, with a regular hole grid as per drawing
Level toleranceOn request
Installation methodBedded on mortar strips, levelled and jointed in the filter basin
Matching filter nozzlesABS, tower or mushroom pattern, long and short handle — supplied separately, sized to the plate hole or socket
Delivery & packingPlates stacked and banded for container or truck shipment; packing arrangement confirmed per order
MOQ / priceOn request — confirm plate size, hole grid, quantity & destination

No filtration performance figures are published for the plate itself: filtration performance is set by the media, the nozzle selection and the filter design, not by the concrete panel.

Where concrete filter plates are used

What we need to quote

Send the following and we will come back with the plate layout, the matching nozzles and the export packing:

If those details are not settled yet, tell us the filter duty and the tank size instead — we will work from that.

Related pages

Compiled from our production and site records for precast concrete filter plates. Sizes and parameters marked on request are confirmed against the specific tank drawing before quotation.